Data set 01
1965 Nixie Valvo
Published operating points and test conditions from this source.
Nixie
Other
AC supply voltage
110 Vrms
Pulsating supply; +/-10%
Series resistor R1
10 kOhm
+/-5%
Bias resistor R2
330 kOhm
Published circuit value
Operating glow voltage
84 V
Published circuit
Ignition electrode current
50 uA
Published circuit
Ignition electrode bias mismatch
- to 5 V
May differ from anode potential by max +/-5 V
Ignition electrode trigger rise
5 to - V
Minimum potential increase required to ignite selected path
Trigger voltage
- to 30 V
Absolute maximum
Cathode current
2 to 4 mA
Absolute range
Cathode resistor
100 to 470 kOhm
Absolute range
Envelope temperature
-55 to 70 degC
Absolute range
Characteristics
Life with one digit continuously displayed
1000 to - h
Minimum
Life with changing display
20000 to - h
Digit changed every 100 h or more often