Data set 01
1969 Nixie Valvo
Published operating points and test conditions from this source.
Nixie
Characteristics
Ignition voltage
170 V
Typical
Burning voltage
140 V
Typical
Extinction voltage
118 V
Typical
Life with changing display
100000 h
At 2 mA; change every 1000 h or more often
Symbol display
direct glow symbols
Cold-cathode symbol indicator
Base
Special 13-pin
Socket B8S 702 28 / alternatives
Other
Continuous cathode current
1 to 3 mA
Absolute range
Recommended cathode current
2 mA
Published operating point
Maximum pulse cathode current
- to 10 mA
Pulse operation
Envelope temperature
- to 70 degC
Absolute maximum