Data set 01
1969 Nixie Valvo
Published operating points and test conditions from this source.
Nixie
Other
Supply voltage
170 V
Nominal
Continuous anode current
2.5 mA
Max; integration time <=20 ms
Pulse anode current
6 to 20 mA
Peak range
Pulse duration
25 to 1500 us
Allowed range
Driven-to-undriven cathode voltage
70 to 115 V
Recommended range
Anode-to-undriven cathode voltage
- to 115 V
Absolute maximum
Decimal point series resistor
10 kOhm
+/-10%
Auxiliary electrode resistor
10 MOhm
+/-10%
Ambient temperature
-50 to 70 degC
Absolute range
Characteristics
Ignition voltage
170 V
Typical
Extinction voltage
118 V
Typical
Cathode resonance frequency
300 to 800 Hz
Published range
Life at 10 mA peak current
100000 h
Changing display; 2 mA average
Life at 20 mA peak current
20000 h
Changing display; 2 mA average
Digit height
15 mm
Side-visible decimal digits