Skip to main content

Nixie ·Nixie

ZM1000R

Long-life cold-cathode ten-digit side-viewing numerical indicator with decimal point. The R variant retains the direct glow-discharge numerical readout function and extended-life design documented for the ZM1000 family.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
16 wire pins
Socket code
-
Base pins
16
Nominal heater
-

Description

ZM1000R is a cold-cathode long-life 10-digit side-viewing indicator with decimal point, classified as Nixie for this batch. The supplied datasheet was reviewed for operating conditions, ratings, and display/counting characteristics.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
16 wire pins
Socket code
-
Base pins
16
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

16 wire pins - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max plate voltage
170 V
Max cathode current
12 mA
Regulator minimum current
1.5 A
Regulator maximum current
4.5 A
Regulator starting voltage
170 V
Regulator maintaining voltage
140 V

Cold-cathode discharge/display section; explicit published limits and operating data are retained as section parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1969 Nixie Mullard

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Numeral/Character Height

    14 mm

    Published mechanical/display data

  • Maximum Peak Cathode Current

    12 mA

    Published peak limit

Characteristic

  • Supply Voltage

    170 V

    Published operating data

  • Minimum Ignition Voltage

    170 V

    Minimum anode-to-cathode voltage necessary for ignition

  • Cathode Current

    2.5 mA

    Published average/normal value

Data set 02

1969 Nixie Valvo

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Supply voltage

    170 V

    0 to 70 degC

  • Anode current

    1.5 to 4.5 mA

    Continuous; integration time >=20 ms

  • Pulse anode peak current

    - to 20 mA

    Pulse operation

  • Pulse duration

    100 to - us

    Pulse operation

  • Pulse anode current

    12 mA

    Typical pulse operation

  • Average anode current

    2.5 mA

    Pulse operation

  • Driven-to-undriven cathode voltage

    65 V

    Pulse operation

  • Decimal point cathode resistor

    100 kOhm

    +/-10%

  • Auxiliary electrode resistor

    10 MOhm

    +/-10%

  • Ambient temperature

    -50 to 70 degC

    Absolute range

Characteristics

  • Ignition voltage

    170 V

    Typical

  • Burning voltage

    140 V

    Nominal characteristic

  • Extinction voltage

    118 V

    Typical

  • Life with changing display

    100000 to - h

    At 2.5 mA; change every 1000 h or more often

Data set 03

196X Nixie Random Datasheets

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Supply Voltage

    170 V

    Published datasheet value

  • Maximum/Normal Cathode Current

    2.3 mA

    Published datasheet value

  • Numeral Height

    14 mm

    Published datasheet value

  • Average Anode Current

    2.3 mA

    Published datasheet value

  • Decimal Point Cathode Resistor

    100 kOhm

    Published datasheet value

Characteristic

  • Ignition/Starting Voltage

    170 V

    Published datasheet value

  • Minimum Cathode/Anode Current

    1.5 mA

    Published datasheet value