Data set 01
1971 Nixie RFT
Published operating points and test conditions from this source.
Nixie
Characteristic
Anode Ignition Voltage
150 V
Published RFT table
Anode Burning Voltage
140 V
Published RFT table
Other
Minimum Operating Voltage
170 V
Published RFT table
Minimum Cathode Current
3 mA
Published RFT table
Maximum Cathode Current
5 mA
Published RFT table
Peak Cathode Current
7 mA
Published RFT table
Minimum Ambient Temperature
-50 degC
Published RFT table
Maximum Ambient Temperature
70 degC
Published RFT table
Symbol Height
15.5 mm
Published RFT table
Maximum Viewing Distance
10 m
Published RFT table
Maximum Bulb Height
49.2 mm
Published RFT table
Maximum Bulb Diameter
22.2 mm
Published RFT table