Skip to main content

Specialized - Switching Tube ·RelayControlSwitch

Z803U

Cold-cathode relay and control switching tube. Available source classification establishes heaterless gas-discharge control service without enough detail for a narrower description.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B7G
Base pins
-
Nominal heater
-

Description

Z803U is a Other device. Gas-filled cold-cathode relay tube with positive starter and anode voltages for sensitive control service.

Socket description

Miniature 7-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B7G
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

RelayControlSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Gas-discharge device.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

RelayControlSwitch

Other

  • Anode supply voltage range

    170 to 290 V

  • Maximum anode supply voltage

    - to 290 V

  • Maximum peak cathode current

    - to 200 mA

Characteristic

  • Starter breakdown voltage at 280 V anode

    128 to 137 V

  • Starter burning voltage

    95 V

  • Ionization delay at 0.5 V overdrive

    2 ms

  • Ionization delay at 4 V overdrive

    0.1 ms

  • Deionization time at 0-20 mA peak

    3.5 ms

  • Deionization time at 20-60 mA peak

    16 ms

  • Maximum starter-breakdown drift per 2000h

    - to 2 %

    Absolute

Data set 02

1971 Mullard Gas Filled Tubes

Published operating points and test conditions from this source.

SECTION 1

RelayControlSwitch

Characteristic

  • Anode maintaining voltage

    105 V

  • Trigger ignition voltage

    132 V

Data set 03

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

RelayControlSwitch

Other

  • Anode maintaining voltage

    105 V

  • Starter ignition voltage minimum

    128 V

  • Starter ignition voltage maximum

    137 V

  • Maximum anode supply voltage

    290 V