Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
Triode
Other
will operated from the low frequencies to above
3000 MHz
will operated from the low frequencies to above 3000 megacycles. Cooling of
with sufficient additional forced air to limit the maximum temperature at
250 C
with sufficient additional forced air to limit the maximum temperature at 250 C.
Peak Pulse-Plate~Supply Voltage
3500 V
Peak Pulse-Plate~Supply Voltage 3500 Volts
Pulse Length
6 us
Pulse Length 6 Microseconds
Negative DC Grid Voltage
150 V
Negative DC Grid Voltage 150 Volts
Positive Peak Grid Voltage
250 V
Positive Peak Grid Voltage 250 Volts
Negative Peak Grid Voltage
750 V
Negative Peak Grid Voltage 750 Volts
Plate Dissipation
10 W
Plate Dissipation 10 Watts
Grid Dissipation
2 W
Grid Dissipation 2.0 Watts
Average Plate Current
10 mA
Average Plate Current 10 Milliamperes
Peak Plate Current
3 A
Peak Plate Current 3.0 Amperes
Average Grid Current
5 mA
Average Grid Current 5.0 Milliamperes
Frequency
3000 MHz
Frequency 3000 Megacycles
Capacitance
conditions+
6.3 V
conditions+ 6.3 Volts
Heater Current
1.05 A
Heater Current 1.05 Amperes
Ep =
600 V
Ep = 600 volts 22,000 24,800 27,500 Micromhos
Voltage =
0 V
Voltage = 0 volts
Grid to Plate 1.89 2.01
2.13 pf
Grid to Plate 1.89 2.01 2.13 pf
Grid to Cathode 6.0 6.5
7 pf
Grid to Cathode 6.0 6.5 7.00 pf
Plate to Cathode, maximum 0.018 0.023
0.029 pf
Plate to Cathode, maximum 0.018 0.023 0.029 pf
Condition+
250 C
Condition+ 250 C
Characteristic
Amplifier
1100 MHz
Amplifier - 1100 Megacycles
Heater Voltage
6 V
Heater Voltage 6.0 Volts
DC Plate Voltage
1700 V
DC Plate Voltage 1700 Volts
DC Grid Voltage
-45 V
DC Grid Voltage -45 Volts
Pulse Length
3.5 us
Pulse Length 3.5 Microseconds
Peak Plate Current
1.9 A
Peak Plate Current 1.9 Amperes
Peak Grid Current
1.1 A
Peak Grid Current 1.1 Amperes
Driving Power during Pulse, approximate
400 W
Driving Power during Pulse, approximate 400 Watts
Peak Useful Power Output, approximate
1500 W
Peak Useful Power Output, approximate 1500 Watts
PublishedData
400 MHz
400 megacycles, recommendations are to be obtained from the tube manufacturer