Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
Triode
Other
megacycles Typical power output is 19 watts at 2500 megacycles and
40 W
to dissipate
100 W
Heater Voltage AC or DG+
6.3 V
Heater Characteristics and Ratings
Heater Current
1 A
Heater Characteristics and Ratings
Cathode Heating Time minimum
60 s
Heater Characteristics and Ratings
Grid to Plate
2 pF
Heater Characteristics and Ratings
Grid to Cathode
6.5 pF
Heater Characteristics and Ratings
Plate to Cathode maximum
0.029 pF
Heater Characteristics and Ratings
DC Plate Voltage
1000 V
MAXIMUM RATINGS
DC Cathode Current
125 mA
MAXIMUM RATINGS
Negative DC Grid Voltage
150 V
MAXIMUM RATINGS
Peak Positive RF Grid Voltage
30 V
MAXIMUM RATINGS
Peak Negative RF Grid Voltage
400 V
MAXIMUM RATINGS
DC Grid Current
50 mA
MAXIMUM RATINGS
Plate Dissipation
100 W
MAXIMUM RATINGS
Grid Dissipation
2 W
MAXIMUM RATINGS
Frequency
2500 MHz
MAXIMUM RATINGS
DC Plate Voltage
600 V
MAXIMUM RATINGS
DC Cathode Current
100 mA
MAXIMUM RATINGS
Plate Dissipation
70 W
MAXIMUM RATINGS
Characteristic
Plate Voltage
600 V
Average Characteristics
Plate Current
70 mA
Average Characteristics
Transconductance
24000 uS
Average Characteristics
Frequency 500
2500 MHz
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
DC Plate Voltage 900
1000 V
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
DC Cathode Current 120
117 mA
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
DC Grid Current 30
27 mA
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
DC Grid Voltage 40
-22 V
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
Useful Power Output 40
19 W
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
Heater current of a bogey tube at Ef
6.3 V
CHARACTERISTICS AND TYPICAL OPERATION (Continued)
not exceed
1200 V