Data set 01
1999 Philips E-Z
Published operating points and test conditions from this source.
Triode
Other
service at frequencies up to
960 MHz
ClassAB;Transposer
HEATING: indirect by A.C. ( [1]
50 Hz
HEATING: indirect by A.C. ( [2]
400 Hz
Heater voltage V¢
6.3 V
Heater current I
5.4 A
Transposer
Cathode heating time ’Ifh min,
180 s
Transposer
Frequency up to
960 MHz
Anode voltage max,
3500 V
Grid voltage max
200 V
Anode dissipation max,
900 W
Grid dissipation max,
0.5 W
Cathode current max,
550 mA
Frequency
470 to 860 MHz
Range values -10 Vto
-30 V
3) Three tone test method (vision carrier [1]
-8 dB
3) Three tone test method (vision carrier [2]
-10 dB
signal
16 dB
Capacitance
Anode to grid
7.8 pF
Grid to cathode and heater
27 pF
Anode to cathode and heater
0.15 pF
Characteristic
Anode voltage
2 kV
Anode current
250 mA
Transconductance
70 mA