Data set 01
1999 Philips E-Z
Published operating points and test conditions from this source.
Triode
Other
service at frequencies up to
960 MHz
ClassAB;Transposer
HEATING indirect by A.C. ( [1]
50 Hz
HEATING indirect by A.C. ( [2]
400 Hz
Frequency f up to
960 MHz
Anode voltage Va max
3500 v
Grid voltage -V max
200 A
Anode dissipation Wi max
1800 w
Grid dissipation Wg max,
0.5 w
Cathode current I max
700 mA
Frequency f
470 to 860 MHz
Anode voltage Va
3000 A
Anode current, no signal condition I
420 mA
Anode current 3) Ia
510 mA
Grid current 1 0to
2 mA
Driving power (sync) Vgdr
5 w
Output power in load Wy
220 w
Power gain G
~ 16 dB
Intermodulation products 4) d
< -52 dB
2) To be adjusted for the stated no-signal anode current. Range values -15Vto
-22 V
4) Three tone test method ( vision carrier [1]
8 dB
4) Three tone test method ( vision carrier [2]
7 dB
signal
17 dB
Anode voltage Va
2500 v
Anode current, no-signal condition Ig
250 mA
Anode current 2) I
500 mA
Grid current I
0 mA
Driving power (sync) ‘gdr
8 w
Output power in load W,
250 w
Power gain G
15 dB
Range values: -10 Vto
-30 V
2)1, at C.'W, output power
250 W
Capacitance
Anode to grid Cag
8.5 pF
Grid to cathode and heater Cg/kf
28 pF
Characteristic
Anode voltage
2 kv
Anode current
400 mA
Transconductance
50 mA