Data set 01
1999 Philips E-Z
Published operating points and test conditions from this source.
Triode
Other
frequencies up to
1000 MHz
ClassAB;Transposer
Frequency f
470 to 860 MHz
Transposer
Anode voltage Vg
1900 V
Transposer
Output power in load (sync) Wy
55 W
Power gain G
19 dB
Heater current If
2.1 A
at reference point ty max
100 °c
Frequency
470 to 860 MHz
Bandwidth ( [1]
-1 dB
Bandwidth ( [2]
9 MHz
Grid voltage 2)
-6.6 v
Anode current, no signal
130 mA
Anode current at zero dB level (vision carrier)
180 mA
Power gain
19 dB
Intermodulation products 3)
-54 dB
3) Three-tone test method (vision carrier [1]
-8 dB
3) Three-tone test method (vision carrier [2]
-7 dB
2) To be adjusted for the stated no-signal anode current
-16 dB
For a vision to sound power ratio of 10:1 : IM products <
56 dB
value, with superimposed a
4.43 MHz
Capacitance
Grid to cathode and heater Cg/xf
17 pF
Anode to cathode and heater Ca/kf
0.05 pF
Characteristic
Anode voltage Va
1900 V
Anode current I,
180 mA
Transconductance S
60 mA