Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Triode
Characteristics
Amplification factor
15
Transconductance
105000 µS
Emission current at UA = UG = 650 V
160 A V
Amplification factor at UA = 4
10 kV, I A = 5 A µ 15 kV
Transconductance at UA = 4 kV, IA = 5 A
105 mA/V kV
Other
Heater voltage
17 V V
Heater current
≈ 265 A A
Anode voltage (dc)
12 kV kV
Grid voltage (dc)
– 1500 V V
Cathode current (dc)
40 A A
Peak cathode current
160 A A
Anode dissipation
180 kW kW
Grid dissipation
2,5 kW kW
600
500 kW kW
Output power
420 0 350 kW kW
Anode voltage (dc)
11 11 11 11 kV kV
Grid voltage (dc)
– 720 – 720 – 740 – 740 V V
Peak control grid voltage (ac)
2200 0 2100 V V
between
2 tubes
Anode current (dc)
2×3 2 × 31,4 2 × 2 2 × 26 A A
Grid current (dc)
2 × 1,1 0 2 × 0,9 A A
Peak grid current
2×8 0 2×7 A A
Anode input power
2 × 33 2 × 345 2 × 22 2 × 286 kW A
Drive power
2 × 1050 0 2 × 850 W W
Anode dissipation
2 × 33 2 × 135 2 × 22 2 × 111 kW kW
Grid dissipation
2 × 280 0 2 × 180 W W
Efficiency η —
61 — 61 %
Effective load resistance (anode to anode) RAA —
350 — 420 Ω Ω
Modulator Triode
2051 V V
Capacitance
Cathode/grid
≈ 260 pF pF
Cathode/anode
≈ 14 pF 1) pF
Grid/anode
≈ 140 pF pF
Modulator Triode
2051 V V
Cooling
(PA + PG + 0,8 PF )
188 kW PF
Equivalent thermal
11300 kJ/min (2700 kcal/min)
at returning water temperature
20 °C approx. 4,4 l/min l/min
at returning water temperature
90 °C approx. 5,1 l/min l/min
at returning water temperature
20 °C approx. 7,3 m 3/min
at returning water temperature
90 °C approx. 8,3 m 3/min
Modulator Triode
2051 V V