Skip to main content

Power - Triode ·Triode

YD1203

Vapor-cooled high-power RF industrial triode designed for Class C oscillator service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
12.2 V / 255 A

Description

Vapour-cooled high-power RF industrial triode. Published filament, capacitance, limiting-rating, and representative Class-C industrial oscillator data were extracted from the supplied Philips sheet.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
12.2 V
Nominal heater current
255 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
200 Ω
Transconductance
0.15 S
Amplification factor
30
Max plate voltage
14400 V
Max plate dissipation
80000 W
Max cathode current
18 A

High-power RF triode; published principal characteristic and limiting values promoted.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Filament voltage

    12.2 V

  • Filament current

    255 A

  • Transconductance

    150000 uS

  • Amplification factor

    30

Capacitance

  • Anode to filament capacitance

    2.7 pF

  • Grid to filament capacitance

    170 pF

  • Anode to grid capacitance

    55 pF

Other

  • Maximum anode voltage

    14400 V

  • Maximum anode current

    18 A

  • Maximum anode dissipation

    80000 W

  • Operating frequency

    30 MHz

    IndustrialClassC

  • Operating anode voltage

    12000 V

    IndustrialClassC;Frequency=30MHz

  • Operating anode current

    13 A

    IndustrialClassC;Frequency=30MHz

  • Anode output power

    123500 W

    IndustrialClassC;Frequency=30MHz

  • Frequency for full ratings

    100 MHz

Construction

  • Cooling system

    Vapour