Data set 01
1999 Philips E-Z
Published operating points and test conditions from this source.
Triode
Characteristics
Filament voltage
8.4 V
Filament current
235 A
Transconductance
90000 uS
Amplification factor
30
Capacitance
Anode to filament capacitance
1.3 pF
Grid to filament capacitance
100 pF
Anode to grid capacitance
45 pF
Other
Maximum anode voltage
13000 V
Maximum anode current
14 A
Maximum anode dissipation
30000 W
Operating frequency
30 MHz
IndustrialClassC
Operating anode voltage
12000 V
IndustrialClassC;Frequency=30MHz
Operating anode current
12 A
IndustrialClassC;Frequency=30MHz
Anode output power
113000 W
IndustrialClassC;Frequency=30MHz
Frequency for full ratings
100 MHz
Construction
Cooling system
ForcedAir