Skip to main content

Power - Triode ·Triode

Y572

Rugged planar triode, former 8906 designation, for CW/pulsed oscillator, multiplier, modulator, and regulator service to 3 GHz.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6 V / 1 A

Description

EIMAC Y572 is explicitly identified as the former designation of 8906. Rugged planar triode for CW or pulsed oscillator, multiplier, modulator, and regulator service to 3 GHz.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.038 S
Amplification factor
80
Max plate voltage
3500 V
Max plate dissipation
10 W
Max grid dissipation
1.5 W
Max cathode current
7.5 A

Promoted values are taken from printed General Characteristics / Maximum Ratings. Additional published conditions and operating data are preserved in parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-Cathode Capacitance

    8 pF

  • Grid-Plate Capacitance

    1.98 pF

  • Plate-Cathode Capacitance

    0.06 pF

Characteristic

  • Cutoff Bias Maximum

    -30 V

Other

  • Frequency CW Maximum

    2.5 GHz

  • Peak Pulse Plate Voltage

    4500 V

  • Pulse Plate Current

    5 A

  • Typical CW Output Power

    45 W

    Frequency=700MHz

Data set 02

1975 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater voltage nominal

    6 V

  • Heater current nominal

    1 A

  • Transconductance

    38000 uS

  • Amplification factor

    80

Capacitance

  • Input/grid-cathode capacitance

    8 pF

  • Output/plate-cathode capacitance

    1.98 pF

  • Grid-plate/feedback capacitance

    0.06 pF

Other

  • Maximum plate voltage

    4500 V

  • Maximum plate dissipation

    10 W

  • Maximum grid dissipation

    1.5 W

  • Maximum cathode or pulse plate current

    7.5 A

  • Maximum rated frequency

    3 GHz

  • CW DC plate voltage

    2500 V

    CW

  • CW DC plate current

    150 mA

    CW

  • CW DC grid current

    45 mA

    CW

  • Conduction/convection plate dissipation

    10 W

    8906

  • Representative DC plate voltage

    630 V

    GroundedGridCWAmplifier

  • Representative useful CW output

    45 W

    GroundedGridCWAmplifier

  • Representative frequency

    700 MHz

    GroundedGridCWAmplifier

  • Pulse peak plate voltage

    4500 V

    Pulse

  • Pulse grid current

    2.5 A

    Pulse

  • Pulse duration

    6 us

    Pulse

Data set 03

1976 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater voltage nominal

    6 V

  • Heater current nominal

    1 A

  • Transconductance

    38000 uS

  • Amplification factor

    80

Capacitance

  • Input/grid-cathode capacitance

    8 pF

  • Output/plate-cathode capacitance

    1.98 pF

  • Grid-plate/feedback capacitance

    0.06 pF

Other

  • Maximum plate voltage

    4500 V

  • Maximum plate dissipation

    10 W

  • Maximum grid dissipation

    1.5 W

  • Maximum cathode or pulse plate current

    7.5 A

  • Maximum rated frequency

    3 GHz

  • CW DC plate voltage

    2500 V

    CW

  • CW DC plate current

    150 mA

    CW

  • CW DC grid current

    45 mA

    CW

  • Conduction/convection plate dissipation

    10 W

    8906

  • Representative DC plate voltage

    630 V

    GroundedGridCWAmplifier

  • Representative useful CW output

    45 W

    GroundedGridCWAmplifier

  • Representative frequency

    700 MHz

    GroundedGridCWAmplifier

  • Pulse peak plate voltage

    4500 V

    Pulse

  • Pulse grid current

    2.5 A

    Pulse

  • Pulse duration

    6 us

    Pulse