Skip to main content

Power - Triode ·Triode

Y503

Eimac high-reliability rugged planar power triode for airborne pulsed RF service to approximately 3 GHz. Substantial plate dissipation and multi-kilovolt capability support demanding military microwave equipment.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6 V / 1 A

Description

The EIMAC Y503 is a high-reliability rugged planar triode for airborne pulsed rf service to 3 ghz.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.03 S
Amplification factor
80
Max plate voltage
2500 V
Max plate dissipation
100 W
Max grid dissipation
2 W
Max cathode current
3 A

Promoted from printed planar-triode general characteristics and pulsed/CW maximum ratings.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    80

  • Transconductance

    30000 uS

Other

  • Maximum plate voltage

    2500 V

  • Maximum plate dissipation

    100 W

  • Maximum grid dissipation

    2 W

  • Maximum pulse cathode current

    3 A

Data set 02

1975 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater voltage nominal

    6 V

  • Heater current nominal

    1 A

  • Transconductance

    25000 uS

  • Amplification factor

    80

Capacitance

  • Input/grid-cathode capacitance

    6.8 pF

  • Output/plate-cathode capacitance

    0.04 pF

  • Grid-plate/feedback capacitance

    2.5 pF

Other

  • Maximum plate voltage

    3500 V

  • Maximum plate dissipation

    100 W

  • Maximum grid dissipation

    2 W

  • Maximum cathode or pulse plate current

    3 A

  • Maximum rated frequency

    3 GHz

  • Grid-pulsed DC plate voltage

    2500 V

    GridPulsed

  • Plate-pulsed peak plate voltage

    3500 V

    PlatePulsed

  • Pulse plate current

    3 A

  • Pulse grid current

    1.5 A

  • Conduction/convection plate dissipation

    10 W

  • Plate dissipation with adequate cooling

    100 W

  • Pulse duration

    6 us

  • Duty factor

    0.0033

  • Representative plate voltage

    2000 V

    GridPulsedOscillator

  • Representative useful output

    750 W

    GridPulsedOscillator

  • Representative frequency

    1.09 GHz

    GridPulsedOscillator

Data set 03

1976 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater voltage nominal

    6 V

  • Heater current nominal

    1 A

  • Transconductance

    25000 uS

  • Amplification factor

    80

Capacitance

  • Input/grid-cathode capacitance

    6.8 pF

  • Output/plate-cathode capacitance

    0.04 pF

  • Grid-plate/feedback capacitance

    2.5 pF

Other

  • Maximum plate voltage

    3500 V

  • Maximum plate dissipation

    100 W

  • Maximum grid dissipation

    2 W

  • Maximum cathode or pulse plate current

    3 A

  • Maximum rated frequency

    3 GHz

  • Grid-pulsed DC plate voltage

    2500 V

    GridPulsed

  • Plate-pulsed peak plate voltage

    3500 V

    PlatePulsed

  • Pulse plate current

    3 A

  • Pulse grid current

    1.5 A

  • Conduction/convection plate dissipation

    10 W

  • Plate dissipation with adequate cooling

    100 W

  • Pulse duration

    6 us

  • Duty factor

    0.0033

  • Representative plate voltage

    2000 V

    GridPulsedOscillator

  • Representative useful output

    750 W

    GridPulsedOscillator

  • Representative frequency

    1.09 GHz

    GridPulsedOscillator