Skip to main content

Rectifier - Half Wave ·Rectifier

XD18

Directly heated high-vacuum power diode for high-voltage rectifier, charging, clipper, and related service. Rated for approximately 40 kV peak inverse voltage, 15 A DC output, and 50 A peak current.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 120 A

Description

XD18 is a high-vacuum diode for high-voltage rectifier, charging, clipper, and/or modulator service as specified in the datasheet.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
120 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max plate dissipation
13000 W
Rectifier peak inverse voltage
40000 V
Rectifier nominal output current
15 A
Rectifier peak forward current
50 A

Published ratings and characteristics promoted where directly established; additional values retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1960 Central Electronic Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak inverse voltage

    40000 V

  • Peak anode current

    50 A

  • Average anode current

    15 A

  • Anode dissipation

    13000 W

  • Clipper filament voltage

    11 V

  • Clipper filament current

    125 A

  • Clipper peak anode current

    300 A

Characteristic

  • Filament voltage

    10 V

  • Filament current

    120 A

Construction

  • Cooling method

    Forced air