Skip to main content

Voltage - Dual Triode (similar) ·Triode-Triode

XCC189

Variable-transconductance twin triode designed for television channel-selector and cascode applications, providing controlled RF gain in television tuner front ends.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
B9A
Base pins
9
Nominal heater
4.5 V / 600 mA

Description

Variable-transconductance twin triode for television channel-selector and cascode applications.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
4.5 V
Nominal heater current
600 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
Yes

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
2500 Ω
Transconductance
0.0125 S
Amplification factor
34
Max plate voltage
130 V
Max plate dissipation
1.8 W
Max cathode current
22 mA

Miniwatt XCC189/4ES8 variable-transconductance twin triode for TV tuner/cascode service. First physical triode, intended grounded-cathode input stage. Typical characteristic point approximately Va 90 V, Ia 15–16 mA, gm 12.5 mA/V, amplification factor 34, plate resistance approximately 2.5 kΩ. Transconductance falls markedly as negative grid bias increases. Maximum operating plate 130 V, dissipation 1.8 W and cathode current 22 mA per section; 550 V is zero-current plate-supply limit, not working anode limit. Heater source discrepancy: Miniwatt 4.5 V 0.6 A; RCA 4ES8/XCC189 lists 4.0 V 0.6 A. Parent 4.5 V retained pending reconciliation.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
2500 Ω
Transconductance
0.0125 S
Amplification factor
34
Max plate voltage
130 V
Max plate dissipation
1.8 W
Max cathode current
22 mA

Miniwatt XCC189/4ES8 variable-mu TV cascode dual triode, second physical section for grounded-grid stage. At typical Va 90 V and Ia roughly 15–16 mA, gm 12.5 mA/V, mu 34, plate resistance approximately 2.5 kΩ; the variable-gain characteristic changes with grid bias. Per-section maxima plate 130 V, dissipation 1.8 W and cathode current 22 mA. Heater source conflict: Miniwatt 4.5 V 0.6 A versus RCA 4.0 V 0.6 A; nominal parent heater retained at 4.5 V pending explicit resolution.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

No source-specific operating conditions are recorded.