Skip to main content

Voltage - Triode (with diode, heptode or hexode) ·Hexode-Triode

X65

Radio receiver frequency changer designed for superheterodyne mixer and oscillator service. Its multi-grid construction performs signal conversion, often integrating local oscillation and mixing within one valve.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
IO
Base pins
8
Nominal heater
6.3 V / -

Description

Triode-hexode all-wave frequency changer.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
IO
Base pins
8
Nominal heater voltage
6.3 V
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Marconi X65 triode oscillator of indirectly heated all-wave/short-wave triode-hexode frequency changer. Manufacturer supplies 250 V anode circuit supply through approximately 30 kΩ and other typical operating conditions, not a clearly declared unrestricted triode maximum anode voltage; prior 250 V maximum field cleared. Octal/IO base and 6.3 V heater.

Section 2

Hexode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Marconi X65 frequency-converter hexode suited to all-wave receivers with good short-wave performance and low frequency pulling. Manufacturer's 250 V anode supply and 100 V screen are typical circuit operating points, not explicitly defined absolute maxima, and maximum voltage fields remain unknown. Published conversion impedance approximately 2.5 MΩ and total cathode current near 11 mA are application-specific characteristics.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1955 Marconi

Published operating points and test conditions from this source.

SECTION 1

Triode

Application

  • Oscillator section function

    Local oscillator

Other

  • Oscillator anode voltage

    250 V

SECTION 2

Hexode

Construction

  • Mixer section identity

    Hexode

Other

  • Mixer anode voltage

    250 V

  • Mixer screen voltage

    100 V

Application

  • Frequency-changer service

    Explicit