Data set 01
1962 ITT
Published operating points and test conditions from this source.
TravelingWave
Characteristic
Operating Frequency Range
496 to 897 MHz
Input Section Bandwidth
10 to 25 MHz
Noise Figure
20 dB
IF Output
50 MHz
Image Rejection
40 dB
Other
Conversion Gain
0 dB
Heater Voltage Maximum
7.5 V
Heater Current Maximum
4.5 A
Cathode Voltage Range
-1200 to -100 V
Cathode Current Maximum
8 mA
Collector Voltage Maximum
250 V
Amplifier Helix Current Maximum
0.5 mA
Oscillator Helix Current Maximum
0.3 mA
Collector Current Maximum
8 mA
Typical RF Frequency
700 MHz
Typical LO Frequency
650 MHz
Typical Image Frequency
600 MHz
Typical IF Frequency
50 MHz
Typical Heater Voltage
6.3 V
Typical Heater Current
1.9 A