Skip to main content

Power - Triode ·Triode

X2153

Eimac rugged planar power triode for continuous-wave or pulsed oscillator, amplifier, and frequency-multiplier service to approximately 6 GHz. Compact construction and multi-kilovolt capability support specialized microwave power.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 650 mA

Description

EIMAC X2153 is explicitly identified as the former designation of 8911. Compact rugged planar triode for CW or pulsed oscillator, amplifier, and frequency-multiplier service to 6 GHz.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
650 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.03 S
Amplification factor
60
Max plate voltage
3000 V
Max plate dissipation
50 W
Max grid dissipation
15 W

Promoted values are taken from printed General Characteristics / Maximum Ratings. Additional published conditions and operating data are preserved in parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-Cathode Capacitance

    5 pF

  • Grid-Plate Capacitance

    1.5 pF

  • Plate-Cathode Capacitance

    0.06 pF

Other

  • Peak Plate Voltage

    3000 V

  • Frequency

    6 GHz

Data set 02

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • viding in excess of [1]

    1 GHz

    viding in excess of 1 kw peak power at 6 GHz.

  • viding in excess of [2]

    6 GHz

    viding in excess of 1 kw peak power at 6 GHz.

  • Heater: Voltage [1]

    6.3 V

    Heater: Voltage ......................... 6.3 ± 597o V

  • Heater: Voltage [2]

    597 V

    Heater: Voltage ......................... 6.3 ± 597o V

  • Current, at [1]

    6.3 A

    Current, at 6.3 volts ................ 0.65 A

  • Current, at [2]

    650 mA

    Current, at 6.3 volts ................ 0.65 A

  • Cathode Heating Time

    60

    Cathode Heating Time ............... 60 sec.

  • Transconductance (Average)

    30

    Transconductance (Average) .................. 30 mmhos

  • Plate Dissipation (maximum)

    2 W

    Plate Dissipation (maximum)2 ................

  • Published value

    2

    2. With forced air cooling or appropriate conduction and/or convection cooling.

  • Ceramic/Metal Seals

    250

    Ceramic/Metal Seals ..... ............. 250OC

  • Class C, Pulsed PULSE DUF(ATIO NI

    3

    Class C, Pulsed PULSE DUF(ATIO NI 3.0 ps

  • PEAK HEATEF}-CATHODE VOLTAGE2 ±

    50 V

    PEAK HEATEF}-CATHODE VOLTAGE2 ±50v

  • FREQUENCY

    6 GHz

    FREQUENCY . 6.0 GHz

  • PEAK PLATE VOLTAGE

    1 V

    PEAK PLATE VOLTAGE ..... 1. For appllcations requiring longer pulse duration

  • Published value

    2

    2. The heater is electrically Isolated from the cathode.

  • Published value

    3

    3. Heater i8 electrlaally

Data set 03

1975 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater voltage nominal

    6.3 V

  • Heater current nominal

    650 mA

  • Transconductance

    30000 uS

  • Amplification factor

    60

Capacitance

  • Input/grid-cathode capacitance

    5 pF

  • Output/plate-cathode capacitance

    1.5 pF

  • Grid-plate/feedback capacitance

    0.06 pF

Other

  • Maximum plate voltage

    3000 V

  • Maximum plate dissipation

    50 W

  • Maximum grid dissipation

    1.5 W

  • Maximum cathode or pulse plate current

    3 A

  • Maximum rated frequency

    6 GHz

  • DC plate voltage

    2000 V

    ClassC;Pulsed

  • Peak plate voltage

    3000 V

    ClassC;Pulsed

  • DC plate current

    100 mA

  • DC grid current

    30 mA

  • Peak grid current

    1.2 A

  • DC grid voltage

    -100 V

  • Pulse duration

    3 us

  • Duty factor

    0.0025

  • Peak heater-cathode voltage

    50 V

Data set 04

1976 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater voltage nominal

    6.3 V

  • Heater current nominal

    650 mA

  • Transconductance

    30000 uS

  • Amplification factor

    60

Capacitance

  • Input/grid-cathode capacitance

    5 pF

  • Output/plate-cathode capacitance

    1.5 pF

  • Grid-plate/feedback capacitance

    0.06 pF

Other

  • Maximum plate voltage

    3000 V

  • Maximum plate dissipation

    50 W

  • Maximum grid dissipation

    1.5 W

  • Maximum cathode or pulse plate current

    3 A

  • Maximum rated frequency

    6 GHz

  • DC plate voltage

    2000 V

    ClassC;Pulsed

  • Peak plate voltage

    3000 V

    ClassC;Pulsed

  • DC plate current

    100 mA

  • DC grid current

    30 mA

  • Peak grid current

    1.2 A

  • DC grid voltage

    -100 V

  • Pulse duration

    3 us

  • Duty factor

    0.0025

  • Peak heater-cathode voltage

    50 V