Data set 01
1962 Eimac
Published operating points and test conditions from this source.
Triode
Capacitance
Grid-Cathode Capacitance
5 pF
Grid-Plate Capacitance
1.5 pF
Plate-Cathode Capacitance
0.06 pF
Other
Peak Plate Voltage
3000 V
Frequency
6 GHz
Power - Triode ·Triode
Eimac rugged planar power triode for continuous-wave or pulsed oscillator, amplifier, and frequency-multiplier service to approximately 6 GHz. Compact construction and multi-kilovolt capability support specialized microwave power.
EIMAC X2153 is explicitly identified as the former designation of 8911. Compact rugged planar triode for CW or pulsed oscillator, amplifier, and frequency-multiplier service to 6 GHz.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Promoted values are taken from printed General Characteristics / Maximum Ratings. Additional published conditions and operating data are preserved in parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Grid-Cathode Capacitance
5 pF
Grid-Plate Capacitance
1.5 pF
Plate-Cathode Capacitance
0.06 pF
Peak Plate Voltage
3000 V
Frequency
6 GHz
Data set 02
Published operating points and test conditions from this source.
viding in excess of [1]
1 GHz
viding in excess of 1 kw peak power at 6 GHz.
viding in excess of [2]
6 GHz
viding in excess of 1 kw peak power at 6 GHz.
Heater: Voltage [1]
6.3 V
Heater: Voltage ......................... 6.3 ± 597o V
Heater: Voltage [2]
597 V
Heater: Voltage ......................... 6.3 ± 597o V
Current, at [1]
6.3 A
Current, at 6.3 volts ................ 0.65 A
Current, at [2]
650 mA
Current, at 6.3 volts ................ 0.65 A
Cathode Heating Time
60
Cathode Heating Time ............... 60 sec.
Transconductance (Average)
30
Transconductance (Average) .................. 30 mmhos
Plate Dissipation (maximum)
2 W
Plate Dissipation (maximum)2 ................
Published value
2
2. With forced air cooling or appropriate conduction and/or convection cooling.
Ceramic/Metal Seals
250
Ceramic/Metal Seals ..... ............. 250OC
Class C, Pulsed PULSE DUF(ATIO NI
3
Class C, Pulsed PULSE DUF(ATIO NI 3.0 ps
PEAK HEATEF}-CATHODE VOLTAGE2 ±
50 V
PEAK HEATEF}-CATHODE VOLTAGE2 ±50v
FREQUENCY
6 GHz
FREQUENCY . 6.0 GHz
PEAK PLATE VOLTAGE
1 V
PEAK PLATE VOLTAGE ..... 1. For appllcations requiring longer pulse duration
Published value
2
2. The heater is electrically Isolated from the cathode.
Published value
3
3. Heater i8 electrlaally
Data set 03
Published operating points and test conditions from this source.
Heater voltage nominal
6.3 V
Heater current nominal
650 mA
Transconductance
30000 uS
Amplification factor
60
Input/grid-cathode capacitance
5 pF
Output/plate-cathode capacitance
1.5 pF
Grid-plate/feedback capacitance
0.06 pF
Maximum plate voltage
3000 V
Maximum plate dissipation
50 W
Maximum grid dissipation
1.5 W
Maximum cathode or pulse plate current
3 A
Maximum rated frequency
6 GHz
DC plate voltage
2000 V
ClassC;Pulsed
Peak plate voltage
3000 V
ClassC;Pulsed
DC plate current
100 mA
DC grid current
30 mA
Peak grid current
1.2 A
DC grid voltage
-100 V
Pulse duration
3 us
Duty factor
0.0025
Peak heater-cathode voltage
50 V
Data set 04
Published operating points and test conditions from this source.
Heater voltage nominal
6.3 V
Heater current nominal
650 mA
Transconductance
30000 uS
Amplification factor
60
Input/grid-cathode capacitance
5 pF
Output/plate-cathode capacitance
1.5 pF
Grid-plate/feedback capacitance
0.06 pF
Maximum plate voltage
3000 V
Maximum plate dissipation
50 W
Maximum grid dissipation
1.5 W
Maximum cathode or pulse plate current
3 A
Maximum rated frequency
6 GHz
DC plate voltage
2000 V
ClassC;Pulsed
Peak plate voltage
3000 V
ClassC;Pulsed
DC plate current
100 mA
DC grid current
30 mA
Peak grid current
1.2 A
DC grid voltage
-100 V
Pulse duration
3 us
Duty factor
0.0025
Peak heater-cathode voltage
50 V