Skip to main content

Specialized - Switching Tube ·MicrowaveTRSwitch

WF44

Broadband X-band TR gas-discharge cell with separate DC and pre-pulse keep-alive electrodes, designed for branched or balanced radar duplexer systems.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Ferranti WF44 is a broadband X-band T.R. gas-discharge cell with separate D.C. and pre-pulse keep-alive electrodes. It supports branched or balanced duplexer systems and is rated to 200 kW peak transmitter line power.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

MicrowaveTRSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Microwave T.R. gas-discharge cell; device-specific primer, breakdown, leakage, recovery, frequency and power data are retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Ferranti

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Frequency

  • Frequency range

    8500 to 10000 Mc/s

Other

  • Maximum transmitter line power

    200 kW

    Peak

  • Minimum transmitter line power

    4 kW

  • D.C. primer supply voltage

    -1500 to -950 V

    Negative D.C.

  • D.C. primer current

    100 to 185 uA

  • Maximum pre-pulse primer voltage

    -650 V

    Peak, ±10%

  • Maximum pre-pulse primer current

    10 mA

  • Pre-pulse duration

    2 us

    Peak amplitude 650 V ±10%, precedes RF pulse by 0.2 us

  • Storage ambient temperature

    -40 to 100 C

Characteristic

  • Maximum VSWR, low band

    1.4

    8500-8850 Mc/s

  • Maximum VSWR, mid band

    1.25

    8850-9850 Mc/s

  • Maximum VSWR, high band

    1.3

    9850-10000 Mc/s

  • Maximum insertion loss

    1 dB

    Primer energized

  • Maximum total leakage power

    100 mW

    200 kW peak, unpulsed

  • Maximum spike leakage energy, unpulsed

    0.3 erg/pulse

    200 kW peak

  • Maximum spike leakage energy, pre-pulsed

    0.1 erg/pulse

    200 kW peak

  • Maximum primer breakdown power

    250 mW

  • Maximum recovery time to -6 dB

    3 us

  • Maximum arc loss at 4 kW

    0.8 dB

  • D.C. primer operating voltage

    180 to 280 V