Data set 01
1959 Telefunken
Published operating points and test conditions from this source.
Pentode
Characteristics
Plate Voltage
250 V
Screen Voltage
100 V
Plate Current
5 mA
Screen Current
1.8 mA
Transconductance
1800 uS
Control Range
100 ratio
Voltage Radio Detector Converter ·Diode-Diode-Pentode
Double-diode variable-mu pentode combining IF amplification, detection, and automatic gain control, with a remote-cutoff pentode and two physical detector-diode sections.
The WE19 combines a variable-mu IF pentode with two detector diodes for amplification, detection, and AGC.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
3 physical sections, each with unique specifications.
Section 1
No fixed ratings are recorded for this section.
Representative detector diode section.
Section 2
Variable-mu IF pentode.
Section 3
No fixed ratings are recorded for this section.
Physical second diode section added during approved section-structure reconciliation.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Plate Voltage
250 V
Screen Voltage
100 V
Plate Current
5 mA
Screen Current
1.8 mA
Transconductance
1800 uS
Control Range
100 ratio