Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Voltage Regulator
Characteristic
Operating Voltage
90 V
Voltage Regulator ยทVoltageRegulator
Cold-cathode 90 V glow regulator also suitable for relaxation-oscillator and spark-over protection applications.
VR90 is a VoltageRegulator device. Cold-cathode glow-discharge voltage regulator; also suitable for relaxation-oscillator and spark-over protection service.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN2K | A | K โ Cathode | Unverified EIA Base Connections, printed page 127, 4AJ |
| PIN5P | A | P โ Plate (Anode) | Unverified EIA Base Connections, printed page 127, 4AJ |
1 physical section, each with unique specifications.
Section 1
Glow-discharge voltage-regulator section.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Operating Voltage
90 V
Data set 02
Published operating points and test conditions from this source.
Operating voltage
90 V
Ionization voltage
110 V
Regulation over operating-current range
8 V
5to40mA
Minimum DC operating current
5 mA
Maximum DC operating current
40 mA
Minimum anode supply voltage
125 V
Data set 03
Published operating points and test conditions from this source.
Operating voltage
90 V
Maximum regulation
8 V
10to30mA
Minimum operating current
10 mA
Maximum operating current
30 mA
Minimum starting-voltage supply
125 V
Data set 04
Published operating points and test conditions from this source.
DC operating voltage
90 V
DC operating current minimum
10 to - mA
DC operating current maximum
- to 30 mA
DC starting voltage
125 V
Approximate
Voltage regulation
- to 5 V
Ia=10-30mA