Skip to main content

Voltage Pentode - Remote Cutoff (single) ·Pentode

VP13A

Variable-mu or remote-cutoff pentode designed for RF, IF, broadband, or AVC-controlled receiver amplification.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
13 V / 200 mA

Description

Variable-mu HF pentode for AC/DC mains receivers and car radios.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
13 V
Nominal heater current
200 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Pentode

X-ray radiationInterelectrode capacitances
Transconductance
0.0022 S
Max plate voltage
200 V
Max screen voltage
100 V

Promoted values are mapped from the supplied datasheet; additional published ratings, characteristics, capacitances and operating points are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Pentode

Characteristics

  • Plate voltage

    200 V

  • Screen-grid voltage

    100 V

  • Plate current

    4 mA

    ControlGrid=-2V

  • Screen-grid current

    2 mA

  • Control-grid voltage

    -2 V

  • Transconductance

    2200 uS

    Ia=4mA

  • Amplification factor

    2200 ratio

    Published

Other

  • Heater-to-cathode voltage maximum

    125 V