Skip to main content

Voltage - Triode (single) ·Triode

VLS407

Triode for general electronic service. Available source material does not establish a narrower functional application confidently.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
5
Nominal heater
2.1 V / 1 A

Description

VLS407 is a triode described in the Standard Valves datasheet. The source provides construction, electrical constants, limiting conditions, and operating information.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
5
Nominal heater voltage
2.1 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
60000 Ω
Transconductance
0.0005 S
Amplification factor
30
Max plate voltage
190 V
Max cathode current
0.5 mA

Explicit alias/co-designation; values duplicated from the same approved source.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1946 Standard Telephone and Cables

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-anode capacitance

    17 pF

  • Grid-cathode capacitance

    0.5 pF

  • Anode-cathode capacitance

    39 pF