Data set 01
1968 Electronintorg
Published operating points and test conditions from this source.
Rectifier
Characteristic
Heater Voltage
27 V
Heater Current
23 A to 35 A
Published minimum/maximum
Peak Voltage Change
2.5 kV
HeaterVoltage=27V; PeakAnodeCurrent=100A; PulseDuration=1-3us; DutyFactorDenominator=200
Peak Voltage Change
2.65 kV
HeaterVoltage=24.3V; PeakAnodeCurrent=100A; PulseDuration=1-3us; DutyFactorDenominator=200
Warm-up Test Peak Anode Current
90 A
VoltageChange=2.5kV; PulseDuration=1-3us; DutyFactorDenominator=200
Other
Heater Voltage
24.5 to 29.5 V
Limit operating range
Positive Anode Voltage Maximum
25 kV
Peak Anode Reverse Voltage
50 kV
Anode Dissipation Maximum
2.5 kW
Peak Anode Current Maximum
100 A
Minimum Warm-up Time
180 s
Minimum Peak-Anode-Current 1/Duty Factor
200
Maximum Pulse Duration
3 us
Anode Temperature Maximum
150 C
Bulb Temperature Maximum
180 C
Environmental
Vibration Frequency Range
1 to 80 Hz
Vibration Acceleration
98 m/s2
Multiple-Impact Acceleration
392 m/s2
Ambient Temperature
-60 to 85 C
Relative Humidity Maximum
98 percent
Temperature<=35C