Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Gauge
Characteristic
HeaterOrFilamentVoltage
3.1 V
HeaterOrFilamentCurrent
3.5 A
Other
Grid Voltage
150 V
CollectorVoltage
-25 V
Specialized - Gauge Tube ·Gauge
Hot-filament ionization gauge tube designed for high-vacuum pressure measurement down to approximately 10^-7 to 10^-8 mm Hg.
Hot-filament ionization gauge tube for vacuum-pressure measurement down to about 10^-7 mm Hg.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
No fixed ratings are recorded for this section.
Ratings and characteristics promoted from the supplied Sylvania source where explicitly published.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
3.1 V
HeaterOrFilamentCurrent
3.5 A
Grid Voltage
150 V
CollectorVoltage
-25 V
Data set 02
Published operating points and test conditions from this source.
Filament voltage
3 to 7.5 V
Filament current
3.5 A to 5 A
Grid voltage
150 V
Grid current
5 mA
Collector voltage
-25 V
Grid degassing current
7 A
Degassing
Sensitivity for air
90 to 125 uA/micron Hg
Typical sensitivity below one micron
100 uA/micron Hg
Nominal lower pressure capability
1e-7 mm Hg