Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Rectifier
Other
RMS Input Voltage
250 V
Reservoir Capacitance
60 uF
Limiting Resistance
175 ohm
Input=250V; ReservoirCapacitance=60uF
Limiting Resistance
125 ohm
Input=250V; ReservoirCapacitance=32uF
Limiting Resistance
75 ohm
Input=250V; ReservoirCapacitance=16uF
Limiting Resistance
0 ohm
Input=250V; ReservoirCapacitance=8uF
DC Output Voltage
169 V
Input=220Vrms; LoadCurrent=140mA; R=125ohm