X-ray radiationInterelectrode capacitances
No fixed ratings are recorded for this section.
Application: Uhf power amplification. Cathode type: Oxide, indirect heating; Output type: Coaxial; Envelope: Glass with signal conditioning unit in metal envelope; Mass: 500g; Cooling method: Forced air; Frequency range: 10.1 cm; Frequency range Minimum: 8 cm; Frequency range Maximum: 12.2 cm; Output power: 1mW; Gain: 35dB; Filament voltage, v: 2.7; Filament voltage, v Minimum: 2; Filament voltage, v Maximum: 3.3; Filament current, a: 0.75; Filament current, a Minimum: 0.5; Filament current, a Maximum: 1; First anode voltage, v: 102.5; First anode voltage, v Minimum: 5; First anode voltage, v Maximum: 200; Slow-wave circuit voltage, v: 470; Slow-wave circuit voltage, v Minimum: 420; Slow-wave circuit voltage, v Maximum: 520; Control electrode voltage, v: 9; Control electrode voltage, v Minimum: 3; Control electrode voltage, v Maximum: 15; Collector voltage, v: 600; External loading agreement coefficient: 2.5; Noise coefficient: 14dB