X-ray radiationInterelectrode capacitances
No fixed ratings are recorded for this section.
Application: Uhf power amplification. Cathode type: Oxide, indirect heating; Output type: Waveguide; Envelope: Glass with external collector; Mass: 350; Cooling method: Forced air; Frequency range: 3800; Frequency range Minimum: 3400; Frequency range Maximum: 4200; Output power: 6W; Filament voltage, v: 6.3; Filament current, a: 2.3; Filament current, a Minimum: 1.9; Filament current, a Maximum: 2.6; First anode voltage, v: 800; First anode voltage, v Minimum: 650; First anode voltage, v Maximum: 950; Slow-wave circuit voltage, v: 1625; Slow-wave circuit voltage, v Minimum: 1500; Slow-wave circuit voltage, v Maximum: 1750; Collector voltage, v: 1750; Collector voltage, v Minimum: 1500; Collector voltage, v Maximum: 2000; External loading agreement coefficient: 1.2