Data set 01
1957 Philips Receiving and Amplifying Tubes
Published operating points and test conditions from this source.
Tuning Indicator
Characteristic
Heater Voltage
19 V
Heater Current
100 mA
Application
AM receiver tuning indicator
Tuning Indicator ·TuningIndicator
Series-heater fluorescent tuning indicator designed for AM receivers, providing visible tuning accuracy and received-signal indication.
Series-heater tuning indicator for AM receivers.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted from the approved source.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
19 V
Heater Current
100 mA
Application
AM receiver tuning indicator
Data set 02
Published operating points and test conditions from this source.
HeaterVoltageNominal
19 V
Nominal
HeaterCurrentNominal
100 mA
Nominal
Maximum Plate Voltage
250 V
Maximum Plate Dissipation
0.2 W
Data set 03
Published operating points and test conditions from this source.
Supply voltage
200 V
Indicator
Indicator voltage
200 V
Indicator
Anode resistor
0.5 MOhm
Indicator
Grid resistor
3 MOhm
Indicator
Grid voltage
-1 V
Indicator; MaximumShadow
Grid voltage
-14 V
Indicator; MinimumShadow
Plate current
0.35 mA
Indicator; GridVoltage=-1V
Plate current
0.01 mA
Indicator; GridVoltage=-14V