Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Triode
Characteristic
HeaterOrFilamentVoltage
12.6 V
HeaterOrFilamentCurrent
33 A
Grid To Plate Capacitance
11 pF
Input Capacitance
16 pF
Output Capacitance
0.3 pF
Transconductance
17 mA/V
Amplification Factor
32
Cooling
Forced air
Other
MaxPlateVoltage
6.2 kV
ClassC;Telegraphy;Frequency<=75MHz
MaxPlateVoltage
5 kV
ClassC;Telephony
MaxPlateVoltage
4 kV
TV;Frequency=220MHz
MaxCathodeCurrent
1.85 A
ClassC;Telegraphy
MaxPlateDissipation
5 kW
ClassBOrClassC
MaxGridCurrent
350 mA
ClassC
MaxGridDissipation
120 W
Frequency
30 MHz
ClassC;TelegraphyOrFMTelephony
Plate Voltage
6 kV
ClassC;TelegraphyOrFMTelephony
Plate Current
1.5 A
ClassC;TelegraphyOrFMTelephony
Grid Voltage
-400 V
ClassC;TelegraphyOrFMTelephony
Grid Current
310 mA
ClassC;TelegraphyOrFMTelephony
Plate Dissipation
2.1 kW
ClassC;TelegraphyOrFMTelephony
Power Output
6.9 kW
ClassC;TelegraphyOrFMTelephony
LoadPower
5.5 kW
ClassC;TelegraphyOrFMTelephony
Efficiency
76.5 %
ClassC;TelegraphyOrFMTelephony
Frequency
110 MHz
ClassC;TelegraphyOrFMTelephony
Plate Voltage
5 kV
ClassC;TelegraphyOrFMTelephony
Plate Current
1.25 A
ClassC;TelegraphyOrFMTelephony
Grid Voltage
-300 V
ClassC;TelegraphyOrFMTelephony
Grid Current
300 mA
ClassC;TelegraphyOrFMTelephony
Plate Dissipation
1.45 kW
ClassC;TelegraphyOrFMTelephony
Power Output
4.8 kW
ClassC;TelegraphyOrFMTelephony
LoadPower
3.9 kW
ClassC;TelegraphyOrFMTelephony
Efficiency
70 %
ClassC;TelegraphyOrFMTelephony
Plate Voltage
6 kV
ClassB;Audio;TwoTubes;PushPull
Plate Current
3 A
ClassB;Audio;TwoTubes;PushPull
Grid Voltage
-165 V
ClassB;Audio;TwoTubes;PushPull
Grid Current
560 mA
ClassB;Audio;TwoTubes;PushPull
Plate Dissipation
5 kW
ClassB;Audio;TwoTubes;PushPull
Power Output
13.3 kW
ClassB;Audio;TwoTubes;PushPull