Skip to main content

Power - Triode (over 1000V 100W) ·Triode

TY4350

Directly heated all-glass VHF power triode for transmitting service. Approximately 400 W plate dissipation and multi-kilovolt capability provide useful power for VHF oscillator and amplifier circuits.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 10 A

Description

All-glass VHF power triode rated for about 400 W anode dissipation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
10 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.004 S
Amplification factor
35
Max plate voltage
4000 V
Max plate dissipation
400 W
Max grid dissipation
20 W
Max cathode current
600 mA

Promoted from published Mullard absolute-maximum/limiting-value and characteristic tables; service-specific limits retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • HeaterOrFilamentVoltage

    10 V

  • HeaterOrFilamentCurrent

    10 A

  • Grid To Plate Capacitance

    6.3 pF

  • Input Capacitance

    12.3 pF

  • Output Capacitance

    8.5 pF

  • Transconductance

    4 mA/V

  • Amplification Factor

    35

  • MaximumOperatingFrequency

    75 MHz

Other

  • MaxPlateVoltage

    4 kV

    ForcedAirCooling

  • MaxPlateVoltage

    3 kV

    NaturalCooling

  • MaxPlateDissipation

    400 W

    ForcedAirCooling

  • MaxPlateDissipation

    300 W

    NaturalCooling

  • MaxGridCurrent

    100 mA

  • MaxGridDissipation

    20 W

  • MaxCathodeCurrent

    600 mA

  • PeakCathodeCurrentMaximum

    3 A

  • Frequency

    20 MHz

    ClassC

  • Plate Voltage

    4 kV

    ClassC

  • Grid Voltage

    -200 V

    ClassC

  • Plate Current

    450 mA

    ClassC

  • Grid Current

    75 mA

    ClassC

  • Plate Dissipation

    360 W

    ClassC