Skip to main content

Power - Triode (over 1000V 100W) ·Triode

TY1250A

Forced-air-cooled very-high-power transmitting triode for major RF power applications. Approximately 100 kW plate dissipation and 15 kV capability support extremely high continuous transmitter output.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
17.5 V / 196 A

Description

Forced-air-cooled very-high-power transmitting triode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
17.5 V
Nominal heater current
196 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.05 S
Amplification factor
27
Max plate voltage
15000 V
Max plate dissipation
100000 W
Max cathode current
20 A

Promoted from published Mullard absolute-maximum/limiting-value and characteristic tables; service-specific limits retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • HeaterOrFilamentVoltage

    17.5 V

  • HeaterOrFilamentCurrent

    196 A

  • Grid To Plate Capacitance

    86 pF

  • Input Capacitance

    116 pF

  • Output Capacitance

    3.4 pF

  • Transconductance

    50 mA/V

  • TransconductanceMaximum

    92 mA/V

    PlateVoltage=3kV;PlateCurrent=50A

  • Amplification Factor

    27

  • Cooling

    Forced air

Other

  • MaxPlateVoltage

    15 kV

    ClassB;AF

  • MaxPlateVoltage

    13.5 kV

    ClassB;Telephony

  • MaxPlateVoltage

    10 kV

    ClassC;Telephony

  • MaxCathodeCurrent

    20 A

  • MaxPlateDissipation

    100 kW

    ClassB;Telephony

  • MaxGridCurrent

    3 A

    ClassC

  • MaxGridVoltageMagnitude

    1.2 kV

    ClassC