Skip to main content

Power - Triode (over 1000V 100W) ·Triode

TY1220A

Forced-air-cooled high-power RF transmitting triode for substantial oscillator and amplifier service. Approximately 20 kW plate dissipation and 13 kV capability provide major professional radio-frequency power.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
8 V / 130 A

Description

Forced-air-cooled high-power RF transmitting triode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
8 V
Nominal heater current
130 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.03 S
Amplification factor
21
Max plate voltage
13000 V
Max plate dissipation
20000 W
Max grid dissipation
1100 W
Max cathode current
5 A

Promoted from published Mullard absolute-maximum/limiting-value and characteristic tables; service-specific limits retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • HeaterOrFilamentVoltage

    8 V

  • HeaterOrFilamentCurrent

    130 A

  • Grid To Plate Capacitance

    23.5 pF

  • Input Capacitance

    45 pF

  • Output Capacitance

    0.9 pF

  • Transconductance

    30 mA/V

  • Amplification Factor

    21

  • Cooling

    Forced air

Other

  • MaximumOperatingFrequency

    30 MHz

  • MaxPlateVoltage

    13 kV

  • MaxCathodeCurrent

    5 A

  • MaxGridVoltageMagnitude

    2 kV

  • MaxGridCurrent

    1.5 A

  • MaxPlateDissipation

    20 kW

  • MaxGridDissipation

    1.1 kW

  • Frequency

    30 MHz

    ClassC

  • Plate Voltage

    12 kV

    ClassC

  • Plate Current

    4.5 A

    ClassC

  • Grid Current

    900 mA

    ClassC

  • Plate Dissipation

    15 kW

    ClassC

  • Efficiency

    72.5 %

    ClassC