Data set 01
1972 Thomson CSF
Published operating points and test conditions from this source.
Klystron
Other
cavity high power sealed-off klystron amplifier able to ,"" \ s ,
4 W
cavity high power sealed-off klystron amplifier able to ,"" \ s ,4
deliver a [1]
30 kW
deliver a 30 kW average power min and a 25 MW peak
deliver a [2]
25 kW
deliver a 30 kW average power min and a 25 MW peak
given center frequency in the range [1]
2700
given center frequency in the range 2700 - 3100 Mc.
given center frequency in the range [2]
3100
given center frequency in the range 2700 - 3100 Mc.
The rf input is made on a
5011
The rf input is made on a 5011 -N type coaxial
The beam focusing is obtained by a TV
19008
The beam focusing is obtained by a TV 19008
RF input UG
22
RF input UG 22 D/U plug
RF output two RG
48
RF output two RG 48/U waveguides with reduced
Active getter input UG
496
Active getter input UG 496/U plug
Heater voltage (a. c or d. c) [1]
25 V
Heater voltage (a. c or d. c) 25V 5% (1)
Heater voltage (a. c or d. c) [2]
5 V
Heater voltage (a. c or d. c) 25V 5% (1)
Heater voltage (a. c or d. c) [3]
1 V
Heater voltage (a. c or d. c) 25V 5% (1)
Hot heater resistance [1]
1
Hot heater resistance 1 IL 10 %
Hot heater resistance [2]
10
Hot heater resistance 1 IL 10 %
Cold heater resistance [1]
0.14
Cold heater resistance 0.14 10
Cold heater resistance [2]
10
Cold heater resistance 0.14 10
Bandwidth . , min
15
Bandwidth . , min 15 Mc
Peak output power min
25 W
Peak output power min 25 MW
Average output power min
30 kW
Average output power min 30 kW
Efficiency (for an output peak power [1]
10 W
Efficiency (for an output peak power 10 MW) min 40
Efficiency (for an output peak power [2]
40 W
Efficiency (for an output peak power 10 MW) min 40
RF input connector US [1]
21 us
RF input connector US 21 D/U ( coaxial line RG 1143/U)
RF input connector US [2]
1143 us
RF input connector US 21 D/U ( coaxial line RG 1143/U)
Heater -cathode connector TV
19201
Heater -cathode connector TV 19201
(
1 V
(1 ) The exact heating voltage is indicated on the testing sheet of each tube.
This voltage is to be observed within +
5 V
This voltage is to be observed within + 5 ~.
Beam voltage
235 kV
Beam voltage 235 kV
Beam current
21 A
Beam current 21f0 A
Output, peak
255
Output, peak 25,5 MW
Output, average
305 kW
Output, average 30,5 kW
Gain
5
Gain 5 db
Bandwidth (- I. db )
30
Bandwidth (- I. db ) 30 Mc
Pulse duration
4
Pulse duration 4 }zS
Heater warm-up time min
15
Heater warm-up time min 15 mn
Heater surge current max
50 A
Heater surge current max 50 A
Beam voltage max
270 kV
Beam voltage max 270 kV
Average applied power max
67.5 kW
Average applied power max 67.5 kW
Efficient d. c pulse duration max
11
Efficient d. c pulse duration max 11 is
Cooling water inlet temperature max
50
Cooling water inlet temperature max 50°C
Heater Connection X4
7
Heater Connection X47