Data set 01
1972 Thomson CSF
Published operating points and test conditions from this source.
Triode
Other
Filament Starting Current Maximum
600 A
Filament Resistance Cold
0.006 ohm
Cathode-Grid Capacitance
64 pF
Grid-Anode Capacitance
39 pF
Anode-Cathode Capacitance
1.5 pF
DC Anode Current Maximum
7 A
DC Grid Current Maximum
900 mA
Input Power Maximum
90 kW
Frequency Full Load Maximum
30 MHz