Data set 01
1972 Thomson CSF
Published operating points and test conditions from this source.
Magnetron
Characteristic
Frequency range
2900 to 3100 MHz
Heater voltage
16 V
Heater current
3.1 A
Peak anode voltage minimum
30000 V
Device type
Pulsed magnetron
Other
Peak output power minimum
800 kW
Peak anode voltage maximum
30000 V
Pulse duration minimum
1 us
Pulse duration maximum
2 us
Duty cycle
0.0005
Peak anode current
70 A
Frequency pulling maximum
15 MHz