Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Triode
Characteristic
Filament voltage
12.6 V
DirectlyHeated
Filament current
33 A
DirectlyHeated
Amplification factor
32
Published
Transconductance
15000 µS
Published
Other
Maximum plate voltage
7200 V
Published limit
Maximum plate dissipation
6000 W
Published limit
Maximum plate/cathode current
2.2 A
Published limit
Maximum operating frequency
50 MHz
RFService
Plate voltage
6500 V
30 MHz
Plate current
2 A
30 MHz
Plate input power
13 kW
30 MHz
Plate dissipation
3.5 kW
30 MHz
Power output
9.5 kW
30 MHz
Capacitance
Plate-to-cathode capacitance
0.3 pF
Published
Grid capacitance
16 pF
Published
Grid-to-plate capacitance
11 pF
Published