Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Triode
Characteristic
Filament voltage
8 V
DirectlyHeated
Filament current
98 A
DirectlyHeated
Other
Maximum plate voltage
13000 V
Published limit
Maximum plate dissipation
20000 W
Published limit
Maximum plate/cathode current
4.8 A
Published limit
Maximum operating frequency
30 MHz
RFService
Maximum starting filament current
210 A
FilamentStarting
Maximum grid current
800 mA
RFService
Plate voltage
12000 V
ClassC 30MHz
Plate current
3.2 A
ClassC 30MHz
Grid current
500 mA
ClassC 30MHz
Plate input power
38.4 kW
ClassC 30MHz
Plate dissipation
9.4 kW
ClassC 30MHz
Power output
29 kW
ClassC 30MHz