Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Triode
Characteristic
Filament voltage
6.3 V
DirectlyHeated
Filament current
130 A
DirectlyHeated
Amplification factor
17.5
Published
Transconductance
23000 µS
Published
Other
Maximum plate voltage
8000 V
Published limit
Maximum plate dissipation
10000 W
Published limit
Maximum plate/cathode current
4 A
Published limit
Plate voltage
6000 V
IndustrialRF
Plate current
3.3 A
IndustrialRF
Plate input power
19.8 kW
IndustrialRF
Plate dissipation
5.5 kW
IndustrialRF
Power output
14.3 kW
IndustrialRF
Alternate maximum plate dissipation
15 kW
Special cooling condition
Capacitance
Plate-to-cathode capacitance
1.2 pF
Published
Grid capacitance
44.5 pF
Published
Grid-to-plate capacitance
33.5 pF
Published