Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Triode
Characteristic
Filament voltage
3.4 V
DirectlyHeated
Filament current
19 A
DirectlyHeated
Amplification factor
33
Published
Alternate filament voltage
3.3 V
600-750 MHz
Alternate filament voltage
3.2 V
750-900 MHz
Other
Maximum plate voltage
2200 V
Published limit
Maximum plate dissipation
400 W
Published limit
Maximum plate/cathode current
400 mA
Published limit
Maximum operating frequency
900 MHz
RFService
Plate voltage
2000 V
UHF
Plate current
200 mA
UHF
Plate input power
800 W
470 MHz
Plate dissipation
290 W
470 MHz
Capacitance
Plate-to-cathode capacitance
0.12 pF
Published