Skip to main content

Power - Triode (over 1000V 100W) ·Triode

TB41250

Directly heated Philips transmitting triode suitable for grounded-grid RF power operation. Rated for approximately 450 W plate dissipation and 4 kV plate voltage, with moderate gain and substantial transmitting power capability.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 9.9 A

Description

TB41250 is a Philips grounded-grid-capable transmitting triode. The supplied datasheet provides direct-filament data, RF/AF ratings, capacitances and high-power operating conditions.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
9.9 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.0045 S
Amplification factor
28
Max plate voltage
4000 V
Max plate dissipation
450 W

Published filament, capacitance, typical characteristics, limiting values and RF/AF operating tables reviewed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V4

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Filament voltage

    10 V

    DirectlyHeated

  • Filament current

    9.9 A

    DirectlyHeated

  • Amplification factor

    28

    Published

  • Transconductance

    4500 µS

    Published

Capacitance

  • Plate capacitance

    0.17 pF

    Published

  • Grid capacitance

    8 pF

    Published

  • Grid-to-plate capacitance

    7 pF

    Published

Data set 02

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Filament voltage \ 10 Vv

    10 a

    Filament voltage \ 10 Vv

  • Filament current I

    99 a

    Filament current I = 99 A

  • Anode to all other elements except grid C,

    170 mA

    Anode to all other elements except grid C, = 0.17 pF

  • Grid to all other elements except anode Cg

    8 a

    Grid to all other elements except anode Cg = 8.0 pF

  • Anode to grid Cag

    7 A

    Anode to grid Cag = 7.0 pF

  • 50 Mc/s, it will be necessary to direct a low-velocity air flow on the anode seal

    50 s

    50 Mc/s, it will be necessary to direct a low-velocity air flow on the anode seal

  • RF power triode JL TB4/1250

    1250 w

    RF power triode JL TB4/1250

  • Wavelength b

    3 W

    Wavelength b = 3 3 3 3

  • Anode voltage vV,

    2500 A

    Anode voltage vV, = 4000 3500 3000 2500

  • Grid voltage Vg

    -200 v

    Grid voltage Vg = -350 =300 ~250 -200

  • Anode current I

    535 A

    Anode current I = 535 535 535 535 mA

  • Grid current Ig

    115 mA

    Grid current Ig = 115 115 115 115 mA

  • Grid input power Wig

    42 w

    Grid input power Wig = 60 54 48 42

  • Anode input power Wia

    1340 A

    Anode input power Wia = 2140 1880 1600 1340

  • Anode dissipation W,

    390 A

    Anode dissipation W, = 450 450 425 390

  • Wavelength A

    3 W

    Wavelength A = 3 3 3

  • Anode voltage Vg

    2500 A

    Anode voltage Vg = 4000 3500 3000 2500

  • Grid resistor Rg

    1800 s

    Grid resistor Rg = 3000 2600 2200 1800

  • Anode current I,

    535 A

    Anode current I, = 535 535 535 535

  • Anode dissipation Wy

    390 A

    Anode dissipation Wy = 450 450 425 390

  • Fig. 2 Grounded grid configuration

    2 nf

    Fig. 2 Grounded grid configuration.

  • Wavelength A

    3 W

    Wavelength A = 3 3 3 3

  • Anode voltage V,

    2500 A

    Anode voltage V, = 4000 3500 3000 2500

  • Grid voltage Vg

    -200 v

    Grid voltage Vg = =350 -300 -250 -200

  • Anode current I,

    35 A

    Anode current I, = 2x535 2x535 2x535 2x535 mA

  • Grid current Ig

    15 mA

    Grid current Ig = 2xI15 2x115 2x115 2x115 mA

  • Grid input power Wig

    12 w

    Grid input power Wig = 2x320 2x274 2x248 2x212

  • Anode input power Wia

    340 A

    Anode input power Wia = 2x2140 2x1880 2x1600 2x1340

  • Anode dissipation W,

    90 A

    Anode dissipation W, = 2x450 2x450 2x425 2x390

  • RF power triode J L TB“/‘25°

    25 w

    RF power triode J L TB“/‘25°

  • Frequency f upto 100 MHz

    100 MHz

    Frequency f upto 100 MHz

  • Wavelength A

    3 W

    Wavelength A = 3 m

  • Anode voltage Va

    3000 A

    Anode voltage Va = 3000 \%

  • Grid voltage Vg

    -375 v

    Grid voltage Vg = ~-375 v

  • Anode current I,

    450 A

    Anode current I, = 450 mA

  • Grid current Ig

    85 mA

    Grid current Ig = 85 mA

  • Grid input power wig

    42 w

    Grid input power wig = 42 w

  • Anode input power Wia

    1350 A

    Anode input power Wia = 1350 w

  • Anode dissipation W,

    300 A

    Anode dissipation W, = 300 w

  • Modulation power Wmod

    675 a

    Modulation power Wmod = 675 W

Other

  • Amplification factor u

    28 A

    Amplification factor u = 28

  • Temperature of anode seal max. 220 el

    220 a

    Temperature of anode seal max. 220 el

  • Temperature of bottom pin seals max. 180 °c

    180 a

    Temperature of bottom pin seals max. 180 °c

  • Bulb temperature max. 250 °¢

    250 a

    Bulb temperature max. 250 °¢

  • Anode connector: 40626 max 118

    118 A

    Anode connector: 40626 max 118

  • Anode voltage

    4000 A

    Anode voltage = max. 4000

  • Anode dissipation

    450 A

    Anode dissipation = max. 450

  • Grid dissipation

    50 s

    Grid dissipation = max. 50

  • Cathode current

    650 a

    Cathode current = max. 650

  • Peak grid AC voltage Vgp

    405 a

    Peak grid AC voltage Vgp = 580 520 460 405 \Y

  • Output power Wy,

    950 w

    Output power Wy, = 1690 1430 1175 950

  • Efficiency n

    71 %

    Efficiency n = 79 76 73.5 71 %

  • Peak grid AC voltage Vgp

    405 a

    Peak grid AC voltage Vgp = 580 520 460 405

  • Output power W,

    908 w

    Output power W, = 1630 1376 1127 908

  • Peak grid voltage Vgp

    405 a

    Peak grid voltage Vgp = 580 520 460 405

  • Output power Wy

    340 w

    Output power Wy = 3380+520 2860+440 2350+400 1900+340

  • Efficiency 7

    71 %

    Efficiency 7 = 79 76 73.5 71 %2)

  • Anode voltage 7 Va

    3000 A

    Anode voltage 7 Va = max. 3000 V

  • Anode dissipation W,

    300 A

    Anode dissipation W, = max. 300 W

  • Grid dissipation Wg

    50 s

    Grid dissipation Wg = max. 50 w

  • Grid current Ig

    115 ma

    Grid current Ig = max. 115 mA

  • Cathode current Iy

    550 a

    Cathode current Iy = max. 550 mA

  • Peak grid AC voltage Vgp

    580 a

    Peak grid AC voltage Vgp = 580 \%

  • Output power Wo

    1050 w

    Output power Wo = 1050 w

  • Efficiency n

    78 %

    Efficiency n = 78 %

  • Anode voltage V,

    4000 A

    Anode voltage V, = max. 4000

  • Anode dissipation W,

    450 A

    Anode dissipation W, = max. 450

  • Grid dissipation Wg

    50 s

    Grid dissipation Wg = max. 50

  • Cathode current I,

    700 a

    Cathode current I, = max. 700 mA

  • Peak cathode current Ikp

    5 a

    Peak cathode current Ikp = max. 5