Skip to main content

Power - Triode (over 1000V 100W) ·Triode

TB31000

Directly heated Philips transmitting triode for RF and AF power service. Rated for approximately 500 W plate dissipation and 3 kV plate voltage, placing it among the higher-power radiation-cooled TB-series types.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
12 V / 8.5 A

Description

TB31000 is a Philips RF/AF transmitting triode. The supplied datasheet provides direct-filament data, RF/AF ratings, capacitances and high-power operating conditions.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
12 V
Nominal heater current
8.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
3000 V
Max plate dissipation
500 W
Max cathode current
700 mA

Published filament, capacitance, typical characteristics, limiting values and RF/AF operating tables reviewed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V4

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Filament voltage

    12 V

    DirectlyHeated

  • Filament current

    8.5 A

    DirectlyHeated

Other

  • Maximum plate voltage

    3000 V

    Published limit

  • Maximum plate dissipation

    500 W

    Published limit

  • Maximum cathode/plate current

    700 mA

    Published limit

Capacitance

  • Plate capacitance

    7 pF

    Published

  • Grid capacitance

    15 pF

    Published

  • Grid-to-plate capacitance

    8 pF

    Published

Data set 02

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Capacités Cg

    15 a

    Capacités Cg = 15 pF