1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Triode
Characteristic
Filament voltage
12 V
DirectlyHeated
Filament current
2.7 A
DirectlyHeated
Amplification factor
27
Published
Other
Maximum plate voltage
2000 V
Published limit
Maximum plate dissipation
130 W
Published limit
Maximum cathode/plate current
230 mA
Published limit
Capacitance
Plate capacitance
5.4 pF
Published
Grid capacitance
8.2 pF
Published
Grid-to-plate capacitance
5.5 pF