Skip to main content

Power - Triode ·Triode

T501

Power transmitting triode intended for RF amplification, oscillation, modulation, or industrial RF service. Manufacturer documentation emphasizes professional radio-frequency operation and substantial power handling.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Radiation-cooled triode for AF/RF power amplification and oscillator service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
1500 V
Max plate dissipation
70 W
Max cathode current
180 mA

Published ratings and characteristics promoted where reliably recoverable from the approved sheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1969 Brown Boveri

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum Frequency

    100 MHz

  • RF/Output Power

    180 W

    Quick Reference, stated operating class where applicable

  • Maximum Anode Current

    180 mA