Skip to main content

Specialized - Thyratron ·Triode

T41

Thyratron scanning generator for television line and frame time bases. Controlled gas discharge produces relaxation sweep waveforms.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
4 V / 1.5 A

Description

Thyratron scanning generator for television line and frame time bases.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
4 V
Nominal heater current
1.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
400 V
Max cathode current
500 mA

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1960 Mazda

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Voltage drop at 150 mA

    40 V

Other

  • Maximum peak-to-peak scan output

    120 V

Capacitance

  • Anode-earth capacitance

    3.75 pF

  • Grid-earth capacitance

    4.5 pF