Data set 01
199X Svetlana
Published operating points and test conditions from this source.
Triode
Characteristic
Voltage (AC or DC) 6.3 ±
0.3 V
SourcePage1-2
Current
4 A
SourcePage1-2
Plate resistance
2500 ohms
SourcePage1-2
Grid to plate
8 pF
SourcePage1-2
Grid to filament
7 pF
SourcePage1-2
Other
DC plate voltage
800 V
SourcePage1-2
Maximum-signal DC plate current
160 mA
SourcePage1-2
Grid Current
50 mA
SourcePage1-2
DC plate voltage 450
800 V
TypicalOperation
Grid voltage -9
-45 V
TypicalOperation
Peak grid drive 110
127 V
TypicalOperation
DC Plate current, zero signal 80
80 mA
TypicalOperation
DC Plate current, max signal 100
91 mA
TypicalOperation
Plate load resistance 5000
5000 ohms
TypicalOperation
Power output at distortion above 8.3
13.4 W
TypicalOperation
Grid voltage -16.5
-51 V
TypicalOperation
Peak grid drive, grid-to-grid 360
420 V
TypicalOperation
DC Plate current, zero signal (per tube) 150
150 mA
TypicalOperation
DC Plate current, max signal (per tube) 250
260 mA
TypicalOperation
Plate load resistance 9600
9600 ohms
TypicalOperation
Power output at distortion above 41
91 W
TypicalOperation