Data set 01
1953 RFT Rundfunk Technik
Published operating points and test conditions from this source.
Pentode
Other
HeaterVoltageNominal
10 V
Nominal
HeaterCurrentNominal
16.5 A
Nominal
Maximum Plate Voltage
3000 V
Maximum Screen Voltage
600 V
Maximum Plate Dissipation
700 W
Maximum Screen Dissipation
150 W
MaximumGridDissipation
10 W
Maximum Cathode Current
900 mA
Maximum Frequency
40 MHz
RFOutputPower
1500 W
ClassC; <=3 MHz
Characteristic
Transconductance
9000 µS
Typical